If this is occurring often enough, why not just have a mini-script
that does this that we could put up on the site? If not on the site,
that we could email to folks having the problem. Just a thought.

On 9 Feb 99, at 9:24, Dale E. Reed Jr. wrote concerning:
Re: [Emerald] RadLog Data Type Errors

> The old update script incorrectly set the CallerID field to an
> int, when it should have been a varchar. The easiest way to fix it is to
> use Enterprise manager to edit your RadLogs table, rename the current
> column to CallerIDOLD (and put a default on it like 0), save the changes,
> then add a new column of CallerID, type varchar(15) and save the changes.
>

- Jeff

For more information about this list, including removal,
please see http://www.iea-software.com/maillist.html