RE: [Emerald] HyperARC and RadiusNT

Tom Bilan ( Tom@TDI.NET )
Fri, 12 Feb 1999 17:35:15 -0500

ENH5HIPER>> show pbus set
PBUS SETTINGS
Reported Base :1
Port Density :24
ENH5HIPER>>

System Version: V4.1.72

It works fine for us. I know we had to be patient and wait for the other
people to hang up and stuff before it start reporting the right number.
Also, don't look at 'list networks', that number is always screwed up. Also
make sure you're specifying the right number of ports in emerald.

Tom

-----Original Message-----
From: Billy Huddleston [mailto:billy@nxs.net]
Sent: Friday, February 12, 1999 12:09 PM
To: emerald@iea-software.com
Subject: RE: [Emerald] HyperARC and RadiusNT

I did these commands. However, it still seams that only the first HyperDSP
will show up on
the connection list, anyone on the second card doesn't show up, and from
what I can tell,
the TC is using something around 1000+ for the NAS address for ports on the
second card.

> -----Original Message-----
> From: emerald-request@iea-software.com
> [mailto:emerald-request@iea-software.com]On Behalf Of Tom Bilan
> Sent: Friday, February 12, 1999 8:30 AM
> To: 'emerald@iea-software.com'
> Subject: RE: [Emerald] HyperARC and RadiusNT
>
>
> It's a problem with the HiperARC. Their port numbering is retarded.
>
> I complained to USR a year ago about this and they added the commands:
> SET PBUS REPORTED_BASE
> SET PBUS REPORTED_PORT_DENSITY
>
> USR/3com defaults to 256 per port and if you are running
> hiper DSPs you need
> to change that to 24. If you're running quad modem cards
> it's 4. If you
> have both HiperDSPs and Quads in the same chassis they you
> need to set it to
> 24 (the highest of the two).
>
> Tom Bilan
> TDI Internet
>
> -----Original Message-----
> From: Billy Huddleston [mailto:billy@nxs.net]
> Sent: Thursday, February 11, 1999 8:41 PM
> To: emerald@iea-software.com
> Subject: [Emerald] HyperARC and RadiusNT
>
>
> Just upgraded from a Total Control NetSever to a HyperARC
> with HyperDSP
> cards and Quad Modem cards.
> I've been resarching the archives and find that lots of
> people have been
> having problems with
> the way 3Com does the port numbering. Has anyone figured this
> out? My first
> 23 modems are
> showing up in my online calls okay, but as far as I can tell,
> the second
> card is about 1000
> ports above the first one. Anyone have any ideas? Also, How
> are you suppose
> to configure the
> accounting and radius setup in the TC? I've got it using
> Ascend for the
> "radius type" and
> have Enable Hint Assigned and Enable AcctG checked, (didn't
> check the Enable
> Acct Interval)
>
> Thanks, Billy Huddleston
>
>
>
>
> For more information about this list, including removal,
> please see http://www.iea-software.com/maillist.html
>
> For more information about this list, including removal,
> please see http://www.iea-software.com/maillist.html
>

For more information about this list, including removal,
please see http://www.iea-software.com/maillist.html

For more information about this list, including removal,
please see http://www.iea-software.com/maillist.html